Check IFC classification references

Agree the classification system and edition, decide which objects need a code, and check that every required reference is present, valid and consistent.

Reading time
4 min
For
BIM coordinators, information managers and model reviewers
Learning objective
Define a classification requirement and run a repeatable check that reports missing, invalid and inconsistent codes.

IFC entity type and classification are different

Every IFC object has an entity type defined by the IFC schema, such as IfcWall, IfcDoor or IfcFlowTerminal. A classification reference is additional information that places the object in a project or national system, such as Uniclass, OmniClass, CoClass or NL-SfB, using that system's code and title.

The two answer different questions. The entity type says what kind of object the schema considers it to be; the classification code says how the project groups it for cost, specification, maintenance or handover. A model can be structurally valid IFC and still fail a classification requirement because required codes are missing, belong to the wrong system or edition, or do not exist in the agreed table.

How IFC stores a classification reference

IFC element table
IFC elementRoleWhat to check
IfcClassificationDescribes the system itself: its name, source, edition and edition dateThe system name and edition match the project requirement
IfcClassificationReferenceOne code from that system, with its identification and name, pointing to the system it comes fromThe code exists in the agreed table and its name matches
IfcRelAssociatesClassificationLinks a classification reference to the objects or types it applies toEvery object that needs a code is linked, directly or through its type

Write the requirement before checking

  • Name the system and the edition or table, and say how a newer edition will be handled during the project.
  • Define which objects need a code: by IFC entity, by predefined type, by discipline or by a property such as an asset flag.
  • State whether the code belongs on the occurrence, on its type or on both, and which applies when they differ.
  • Specify the expected format: separators, letter case, leading zeros and whether a title must accompany the code.
  • Say whether more than one system may be used on the same object and how each is identified.
  • Record who assigns codes in each discipline model.

Where the project uses buildingSMART IDS, a classification requirement can be written as a classification facet that names the system and, optionally, the allowed values, applied to the objects the specification selects. Keep the written requirement and the IDS file under the same revision control.

Run a repeatable check

  1. Confirm the system

    List every classification system in the file and compare its name and edition with the requirement. An unexpected second system often reveals an authoring template that was not updated.

  2. Find missing codes

    Select the objects the requirement applies to and report each one without a reference from the agreed system, taking codes inherited from its type into account as the requirement specifies.

  3. Validate the values

    Compare every code with the agreed table. Report codes that do not exist, are formatted differently or use a heading that is too general for the object.

  4. Check consistency

    Report objects whose occurrence and type carry different codes, and objects of the same type with different codes where the requirement expects one.

  5. Record the result

    Record the file, revision, rule set and the counts of passed, failed and not-checked objects, and list every accepted exception with its owner.

The check can run in an IDS-capable checker, in the authoring application or as a script. Whichever you use, run the same rule set on every revision so results can be compared.

Common failures and their causes

Finding table
FindingLikely causeTypical correction
Codes exist in the authoring model but not in the IFC fileThe export mapping does not include the classification parametersMap them to IFC classification references in the export settings and export again
Correct codes, wrong system name or editionAn outdated template or object libraryUpdate the system definition at the source and export again
Codes stored as plain propertiesA property-based workaround in the exportAgree whether a property is acceptable; if not, change the mapping
One object type with different codesCodes assigned per occurrence without coordinationAssign the code on the type, or apply a rule in the authoring tool
Code too generalA default heading used as a placeholderReplace it with the most specific code the requirement asks for

Correct classification at the source and export again. Editing a delivered IFC file directly breaks the link with the authoring data, and the edit has to be repeated on every revision.